Technical Specification (Polyethylene Septic Tank)
| No | Models | Type-1A | Type-1B | Type-1 | Type-2 | Type-3 | Type-4 (As per IS code of practice) | Type-5 |
|---|---|---|---|---|---|---|---|---|
| 1 | Color (UV Stabilised) | Terracotta | Terracotta/Black | Terracotta/Black | Terracotta/Black | Terracotta/Black | Terracotta/Black | Terracotta/Black |
| 2 | Diameter | 600 mm | 850 mm | 850 mm | 1000 mm | 1000 mm | 1300 mm | 1600 mm |
| 3 | Length | 2000 mm | 2000 mm | 2500 mm | 2300 mm | 2800 mm | 2600 mm | 3200 mm |
| 4 | Thickness | 10 mm | 10 mm | 10 mm | 10 mm | 10 mm | 16 mm | 16 mm |
| 5 | No. of Chambers | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| 6 | No. of Manholes | 2 | 2 | 2 | 1 | 2 | 2 | 2 |
| 7 | Size of Manholes | 300 mm (Dia) | 300 mm (Dia) | 300 mm (Dia) | 550 mm (Dia) | 550 mm (Dia) | 550 mm (Dia) | 550 mm (Dia) |
| 8 | Dia of inlet & outlet pipe | 110 mm | 110 mm | 110 mm | 110 mm | 110 mm | 160 mm | 160 mm |
| 9 | Air vent | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm |
In view of constant research and development, the specifications are subject to change without prior notice.
Modular Underground Tank
Another feather in our cap is the addition of our new member, modular polyethylene underground tank to our family.
The tank is designed by renowned Italian product designer Mr. Giovanni Murattori.
You demand the volume, we have it. These tanks are pre plumbed and modular in design, each module has a capacity of 5000 Ltr. Volume. The tank shape can be modulated to the desired volume and can be shipped to site.
These tanks are light weight, easy to install, temperature resistant from-35 to +60, cent percent leak proof, smooth interiors, resistant to acids, alkalis and load bearing.
Tanks are provided with additional extension risers, if required to attain the finish level. The lids are double walled for extra safety.
Tanks can be colored as per the choice of clients to meet the color code requirement.
Perforated Pipes & Endcaps Suitable for Manhole and Soakaway Rings
UNITED Manhole and Soakaway Rings
Manhole chamber rings are manufactured in polyethylene with tongue and groove joints designed to accommodate modular vertical expansion.
Manhole rings can be supplied as plain ring or with perforations
Designers and users should ensure that they have taken into account the current requirements for manhole access as detailed in the Health and Safety Code of Practice, Regulations and Guidance issued by the Health and Safety Executive and other relevant requirements.
Manhole and soakaway depths are nominal, actual depths may vary.
Calculation of Storage Capacity
The effective depth of a soakaway chamber, h, is defined as the depth between the invert level of the lowest pipe entering the chamber and the base of the chamber.
To calculate the required storage capacity BS 8301: 1985 recommends that a rainfall depth of 12 mm be taken over the entire drainage area. The required effective depth of the soakaway can be calculated from the following equation.
h = 0.048AπD2
where A = Area to be drained (m2)
D = Soakaway diameter (m)
h = effective depth (m)
Sump Tank
This tank has been designed to reduce buoyancy effect during monsoon, preventing it from floating during dry run of the tank. It is also provided with leakproof threaded lid to avoid infiltration of sub soil water. The tank is designed to withstand external soil pressure.
Vertical Septic Tank
The sump tank is also designed to be used as vertical Septic tank, with additional attachments inside. The tank is coloured in Terracotta colour to match the international colour code for sewage system.
Water Storage Tank